; $Id: dmcntain.e,v 5.2 2001/06/01 22:08:16 ghwang Exp $
;
; dmContainment class errors
;
.facility DM_CONTAINMENT
.severity ERROR
CANT_FETCH D "Cannot fetch - Invalid object ID %s"
;
;CAUSE: Could not fetch an object with the given id.
;ACTION: This is probably caused by a bad ID. Or, possibly, a connection
; to the Documentum server could not be established.
;
NEED_PRIV_FOR_CHANGE SS "The current user %s has insufficient privileges to save or destroy %s containment."
;
;CAUSE: A user with insufficient privileges tried to
; save or destroy a containment object.
;ACTION: See your sysadmin.
;
BAD_PARAM S "Invalid object id %s specified."
;
; CAUSE: Used for internal purpose.
; ACTION: Report to Docuemtum.
;
CURSOR_FAIL SS "The following query %s generated the following database %s error"
;
; CAUSE: Used for internal purpose.
; ACTION: Report to your sys admin.
;
UPDATE_FAIL SS "Database update on the following table %s generated the following database %s error."
;
; CAUSE: Used for internal purpose.
; ACTION: Report to your sys admin.
;
FETCH_FAIL SS "Database fetching on the following table %s generated the following database %s error."
;
; CAUSE: Used for internal purpose.
; ACTION: Report to your sys admin.
;
INVALID_COMPONENT D "Component object with id %s does not exist."
;
; CAUSE: The component could be destroyed by another user.
; ACTION: Please make sure that the chosen component object is still
; in the docbase.
;
.severity FATAL
INIT1 "The dmContainment type was found in the database without a version stamp."
;CAUSE: Unknown.
;ACTION: Report this message and any parameters to your Documentum site
; representative.
;
INIT2 II "Version stamp %d was expected to be %d."
;CAUSE: The version stamp that the dmContainment object software expected was
; different from the actual version stamp in the database.
;ACTION: You must upgrade your DocuServer database to conform to the
; software that you are running. If your software and data are
; consistent, then report a bug.
; Also, Report this message and any parameters to your Documentum site
; representative.
INIT3 "The type manager returned an error storing the dmContainment type."
;CAUSE: Unknown.
;ACTION: Look at the error logged by the type manager.
; Report this message and any parameters to your Documentum site
; representative.
INT1 S "The following database query %s could not be executed."
;
;CAUSE: Inconsistency between the server and the sysobject type.
;ACTION: Look at the error logged by the database.
; Report this message and any parameters to your Documentum Site
;
INIT4 "The type manager returned an error converting the dm_containment type."
;CAUSE: Unknown.
;ACTION: Look at the error message logged by the type manager.
; Report this message and any parameters to your Documentum Site
; Representative.
TYPE_CONVERSION I "Failed to convert type dm_containment to version %d."
;
; CAUSE: Type conversion failed.
; ACTION: Report the problem.
;